Technical Q & A

Technical Q & A

Current location:HOME>>NEWS>>Technical Q & A

How to maintain the hydraulic lift

Date:2021-01-07Visits:220

  When using the hydraulic lift, you should often check, protect and protect it. This can not only extend the service life of the hydraulic lift, but also make it work with greater power. Of course, the hydraulic lift also has its regular repair time and protection methods

  1. Normal protection (per shift).

  2. After 1500 hours of elevator operation, minor repair of mechanical and electrical systems.

  3. After 5000 hours of elevator operation, the mechanical and electrical systems should be repaired.

  4. Overhaul the mechanical and electrical system after 10000 hours of operation.

  Next, let's talk about the protection and protection of elevator mechanical equipment

  1. The brake of each organization should always check and adjust the gap between brake pad and brake wheel to ensure sensitivity and reliability. On the conflict surface, there should be no dirt. If there is dirt, it is necessary to wash it off with gasoline or thinner.

  2. The smoothness of reducer, gearbox, external gear, etc. and the hydraulic oil are carried out according to the requirements in the smoothness table.

  3. Pay attention to check whether there are broken wires and loose strands in each wire rope. If the relevant rules are exceeded, it is necessary to replace them immediately. The protection of wire rope shall be strictly in accordance with gb5144-85.

  4. The hydraulic lifting platform often checks the connection condition of each part, if it is loose, it should be tightened. Check the tightness of the connecting bolt when the elevator body is under pressure (the method of rotating arm can be used to form the compression condition). It is necessary to have a split pin for all connecting shafts and open it fully.

  Check whether the organization can work normally, and if necessary, clean up the noise.

  6. When setting, disassembling and adjusting the reverse structure, it is necessary to ensure that the center line of the reverse structure reducer is parallel to the center line of the gear, the meshing surface is not less than 70%, and the meshing gap is appropriate.

  7. Always check whether all wires and cables are damaged. To timely bandage and replace some of the damage.

  8. When the motor is overheated, park the car in time, clean up the faults, and then keep running. The motor bearing should be smooth.

  9. The touch surface of each brush should be kept clean, and the brush pressure should be adjusted to make its touch area not less than 50%.

  10. All control boxes and distribution boxes shall be kept clean and the dust on electrical equipment shall be cleaned in time.

  11. The opening and closing of the contact of the travel switch of each safety equipment should be reliable, and the contact crater should be polished in time.

  Our company's lifting platform, elevator, lifting platform start from every detail, every product strive to be refined.


Share:
CLOSE

Telephone:(+86)0523-88818588

Fax:(+86)0523-88985998

Address:NO.83,Xing Jiang Road,Jiang Yan District,Tai Zhou City,Jiang Su Province,China

Jinglong machinery